Metalizing Standards
Information On Commonly Used Specifications For Metalizing
Operations Spec:
- AMPP / NACE Standard No. 12/AWS C2.23M/SSPC CS-23 Standard Practice
Other TSC Specs:
- AWS C2.23M/C.23:2003, NACE No. 12, SSPC-CS 23.00, Joint Specification for the Application of Thermal Spray Coatings (Metallizing) of Aluminum, Zinc, and Their Alloys and Composites for the Corrosion Protection of Steel
- AWS C2.16/C2.16M:2002, Guide for Thermal Spray Operator Qualification
- AWS C2.25/C2.25M:2012, Specification for Thermal Spray Feedstock – Wire and Rods
- AWS C2.21M/C2.21, Specification for Thermal Spray Equipment Acceptance Inspection (Supersedes: AWS C2.2, Recommended Practices for Metallizing with Aluminum and Zinc for Protection of Iron)
- ANSI/AWS C2.18-93R, Guide for the Protection of Steel with Thermal Sprayed Coatings of Aluminum and Zinc and their Alloys and Composites
ASTM A780 – Practice for Repair of Damage and Uncoated Areas of Hot-Dip Galvanized coatings
- Zinc-based Soldiers
- Zinc-Rich Paint
- Zinc Spray Metalizing
Required Coating Thicknesses for the Repair Area are specified in American Society for Testing and Materials (ASTM) Standards:
- A780 – Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings
- Galvanized coating repair thickness requirements vary, depending on the application method and repair material used
- Materials:
- Zinc
- Aluminum
- 85 Zn/15 Al
- A123 – Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products.
- Restrictions:
- Repair area must be ≤1” in its narrowest dimension
- The total repairable area can be no more than ½% of the accessible surface area to be coated, or 36 in² per short-ton of piece weight – whichever is less
- Restrictions:
- A153 – Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware
- Repair Restrictions for Small Parts, Hardware & Fasteners:
- Total repair area for touch-up of bare spots can be no more than 1% of the area to be coated, excluding threaded areas of the piece
- Bare spots and touch-up are not allowed on threaded areas
- Repair Restrictions for Small Parts, Hardware & Fasteners:
- A767 – Specification for Zinc-Coated (Galvanized) Steel Bars for Concrete Reinforcement
- Repair Restrictions for Reinforcing Steel:
- Repair area can be no more than 1% in any 1’ (foot) length, not including sheared or cut ends
- Repair Restrictions for Reinforcing Steel: